Product name | Cheap bipolar electrosurgical cautery machine | |||||||
Model | VET-200A | |||||||
Working frequency | 360-460 kHz | |||||||
Atmospheric pressure range | 86.0-106.0 kpa | |||||||
Power supply | 220V, 50Hz | |||||||
Rated power of equipment | 880 VA + 10% | |||||||
Environmental temperature range | 5℃~40℃ | |||||||
Power consumption | ≤1000VA | |||||||
Output power | Monopolar: 1-200W | |||||||
Bipolar: 1-50W | ||||||||
Function | Cutting: 1-200W | |||||||
Blend cut 1: 1-150W | ||||||||
Coag 1: 1-110W | ||||||||
Coag 2: 1-80W | ||||||||
Bipolar Coag: 1-50W | ||||||||
Product Features: 1. Unique design of anal conductive rod, no shaving and simple operation. 2. Accurate and efficient soft tissue cutting and coagulation control. 3. With memory function, the power set value of the last use appears when restarting the boot. 4. There was no edema, no fibrous contraction scar and little thermal injury after operation. 5. With a neutral electrode contact quality monitoring circuit, it can detect the contact area between the plate and the patient, and systematically detect and evaluate the effective contact area between the plate and the skin. Once the contact area is found to drop to a dangerous level, the system automatically cuts off the output and gives an alarm prompt. It can detect the use of unipolar and bipolar negative plates. 6.It has the function of automatic compensation, stable output power and minimal loss. 7. It can be used for underwater cutting, including tissue cutting in fat-rich areas. 8. It can be used with argon system, endoscopy, hysteroscopy, etc. 9. Low temperature cutting:ultra fine tungsten wire cosmetic electrode,high temperature resistance,anti-adhesion,high strength,high temperature and high pressure sterilization reuse can quickly cut skin and various tissues,shorten operation time,improve operation efficiency 10. Reduce bleeding:at low power,the tips of the electrodes are centralized to close small and medium-sized bloadvessels and capillaries in an instant,so as to improve the efficiency of the operation. 11. Reduce smoke:low-power work,reduce the generation of surgical smoke,make the operation field clear,shorten the operation time. 12. Minimally invasive and fine:while cutting and separating tissues quickly and accurately.it can protect the surrounding tissues to minimize the exudation of the operation,greatly improve the healing of the operation,and the operation is simple. Compared with the conventional electric knife,the operation is faster and simpler. 13. Bipolar coagulation tweezers:can effectively avoid bad adhesion between tweezers and tissues.Thetweezers are polished by fine computer.The precious metal tweezers have excellent thermal conductivity,can effectively prevent tissue adhesion,and can be used repeatedly in high temperature and high pressure sterilization. |